Benchmark report: the screen read again at the end of the run

Under Wayland the title screen can come before the window is on a screen, so the
report's hardware.display stayed empty (seen end to end in a headless sway).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This commit is contained in:
Ludovic Marie
2026-10-23 03:13:09 +02:00
parent 75d818fad6
commit 213cffcf3e
+4
View File
@@ -239,6 +239,10 @@ fn run(control: &Control, setup: Setup) -> Result<PathBuf, String> {
let status = control.status();
let renderer = &status["renderer"];
// On Wayland the window is on a screen only once it has been shown: ask again.
if report.hardware.display.is_none() {
report.hardware.display = serde_json::from_value(status["display"].clone()).ok();
}
let c = &mut report.conditions;
c.scenario = Some(setup.scenario.clone());
c.seed = Some(SEED.to_string());